CT
₹ 25000 / Piece Get Latest Price
| Transducer Type | Current Transducer |
| Measuring Current | AC |
| Brand | ABB |
| Power | 1000 |
| Voltage | 220 V |
| Usage/Application | Automotive |
| Part Number | ES1000 |
Minimum order quantity: 1 Piece
₹ 18000 / Piece Get Latest Price
| Current Range | 0-800 AMPERE |
| Transducer Type | Current Transducer |
| Output Signal | 100mA |
| Sensing Type | Hall Effect |
| Primary Current | 500 AMPERE |
| Supply Voltage | 24 V DC |
| Mounting Type | Panel Mount |
| Brand | LEM |
| Voltage | 24v +- |
| Power | 500 |
| Input | 12V |
| Usage/Application | abb inverter |
| Part Number | lf505-s/sp13 |
| Usage | AC DRIVE |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
Minimum order quantity: 1 Piece
The LF505‑S is a closed‑loop Hall‑effect current transducer designed for electronic measurement of DC, AC, and pulsed currents, providing galvanic isolation between the high‑power primary circuit and the low‑power secondary measurement circuit. It is well suited for applications in motor drives, power converters, battery systems, UPS units, welding power supplies, and other industrial power electronics.
Primary nominal RMS current (Ipn): 500 A — the rated continuous current capability.
Primary current measuring range (Ip): 0 … ±800 A — operational bidirectional range.
Sensing type: Closed‑loop compensated Hall effect — active flux compensation for high accuracy and linearity.
Turns ratio (Kn): 1 : 5000 (primary to secondary).
Secondary nominal RMS current (Isn): 100 mA — proportional current output.
Output type: Current output that is typically converted to a measurable voltage across a burden resistor in the secondary circuit.
Supply voltage (Vc): ±15 V to ±24 V DC (±5 %) bipolar supply.
Accuracy: ~±0.6 % @ nominal current (Ta = 25 °C).
Linearity error: < 0.1 %.
Response time: Typically < 1 µs to 90 % of final value.
Frequency bandwidth: DC … ~100 kHz (–1 dB point).
di/dt capability: Can accurately follow fast current changes (e.g., > 100 A/µs).
Operating temperature range: –40 °C … +70 °C (typically).
Storage temperature: –40 °C … +85 °C.
Isolation & insulation: Galvanic isolation between primary and secondary circuits, insulated plastic case recognized to UL 94‑V0.
Insulation test: Rated to standard AC insulation tests (e.g., 3 kV RMS @ 50 Hz, 1 min).
Hall‑effect closed‑loop sensing ensures excellent accuracy and wide dynamic range.
Low temperature drift and excellent linearity maintain reliable measurement across industrial conditions.
Fast response and wide bandwidth support monitoring of dynamic and pulsed current profiles.
High immunity to external interference and no insertion losses.
AC variable speed and servo motor drives.
Static converters for DC motor drives.
Battery‑powered systems and UPS units.
Switched‑mode power supplies (SMPS) and welding power supplies.
Industrial current monitoring and protection systems.
₹ 15000 / Piece Get Latest Price
| Measuring Current | AC |
| Transducer Type | Pressure Transducer |
| Brand | Sanghvi |
| Power | 2A |
| Voltage | 220 V |
| Usage/Application | Board |
| Part Number | Csnk500M |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
₹ 6500 / Piece Get Latest Price
| Current Range | 0-200 A |
| Transducer Type | Automotive Current Transducer |
| Measuring Current | AC |
| Output Signal | 0-20 mA |
| Sensing Type | Hall Effect |
| Primary Current | 200 A |
| Supply Voltage | 24 V DC |
| Mounting Type | Din Rail |
| Brand | LEM |
| Linearity Error | Dhab |
| Voltage | 220 V |
| Usage/Application | Automotive |
| Frequncy | 50 Hz |
| Usage | Automotive |
| Accuracy | 0.5 % |
| Frequency Range | 40-60 Hz |
| Phase | Single Phase |
₹ 1500 / Piece Get Latest Price
| Transducer Type | Current Transducer |
| Measuring Current | AC |
| Brand | LEM |
| Power | 2Hp |
| Voltage | 220 V |
| Usage/Application | Industrial |
| Frequncy | 50 Hz |
Minimum order quantity: 1 Piece
₹ 4750 / Piece Get Latest Price
| Transducer Type | Current Transducer |
| Measuring Current | AC |
| Brand | LEM |
| Voltage | 220 V |
| Usage/Application | Automotive |
| Part Number | La200-P Lem |
| Frequncy | 50 Hz |
Minimum order quantity: 1 Piece
₹ 6000 / Piece Get Latest Price
| Transducer Type | Current Transducer |
| Measuring Current | AC |
| Brand | LEM |
| Voltage | 220 V |
| Usage/Application | Industrial |
| Part Number | HAS600-P LEM |
| Frequncy | 50 Hz |
₹ 29999 / Piece Get Latest Price
| Transducer Type | Current Transducer |
| Measuring Current | AC |
| Brand | LEM |
| Voltage | 220 V |
| Usage/Application | Siemen Drive |
| Part Number | Lt1005-T |
| Frequncy | 50 Hz |
Minimum order quantity: 1 Piece
₹ 30000 / Piece Get Latest Price
| Transducer Type | Current Transducer |
| Measuring Current | AC |
| Brand | LEM |
| Voltage | 220 V |
| Usage/Application | Siemen Drive |
| Part Number | Lt1005-S |
| Color | BLUE |
Minimum order quantity: 1 Piece
₹ 30000 / Piece Get Latest Price
| Current Range | O-2400 AMPERE |
| Transducer Type | Current Transducer |
| Output Signal | 4-20 mA |
| Sensing Type | Hall Effect |
| Primary Current | 1000 AMPERE |
| Supply Voltage | 24 V DC |
| Mounting Type | Panel Mount |
| Brand | LEM |
| Power | 1000AMP |
| Voltage | 220 V |
| Usage/Application | Siemen Drive |
| Part Number | LF1005S/SP36 |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
₹ 30000 / Piece Get Latest Price
| Measuring Current | AC |
| Transducer Type | Pressure Transducer |
| Brand | Sanghvi |
| Power | 2 A |
| Voltage | 220 V |
| Part Number | Lf2010-S/Sp6 |
| Frequncy | 50 Hz |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
₹ 125000 / Piece Get Latest Price
| Current Range | 200 A |
| Transducer Type | Current Transducer |
| Output Signal | 10 V |
| Sensing Type | Hall Effect |
| Primary Current | 5 A |
| Supply Voltage | 24 V DC |
| Mounting Type | Din Rail |
| Power | 2000 amp |
| Voltage | 24 V |
| Brand | ABB |
| Accuracy | 0.2 % |
| Frequency Range | 45-65 Hz |
| Phase | Single Phase |
₹ 12500 / Piece Get Latest Price
| Transducer Type | cuurent transducer |
| Measuring Current | AC |
| Brand | lem |
| Linearity Error | Lem |
| Voltage | 220 V |
| Usage/Application | Automotive |
| Part Number | Hta400 |
Minimum order quantity: 1 Piece
₹ 9500 / Piece Get Latest Price
| Transducer Type | current transducer |
| Measuring Current | AC |
| Brand | lem |
| Power | 200 |
| Voltage | 220 V |
| Usage/Application | Drive |
| Part Number | Hta200-S |
Minimum order quantity: 1 Piece
₹ 18000 / Piece Get Latest Price
| Current Range | O-1480 AMPERE |
| Measuring Current | AC |
| Transducer Type | Temperature Transducer |
| Output Signal | 100mA |
| Sensing Type | Hall Effect |
| Primary Current | 500 AMPERE |
| Supply Voltage | 24 V DC |
| Mounting Type | Panel Mount |
| Power | 24v +- |
| Brand | LEM |
| Voltage | 220 V |
| Usage/Application | abb inverter |
| Part Number | LF505-S/SP13 |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The LF505‑S/SP13 is a closed‑loop Hall‑effect current transducer from LEM, engineered to measure high AC and DC currents with galvanic isolation between the primary power circuit and the secondary measurement circuitry. It’s commonly used in industrial power monitoring, drive systems, renewable energy converters, and similar applications.
Hall Effect Technology: Uses a closed‑loop compensated Hall effect sensor. The magnetic field generated by the primary current is sensed by the Hall element and converted into a proportional output signal via feedback control for high accuracy and linearity.
Closed‑Loop Measurement: Ensures superior dynamic response, low offset, and reduced temperature drift compared to open‑loop designs.
₹ 20000 / Piece Get Latest Price
| Current Range | 0-800 AMPERE |
| Transducer Type | Pressure Transducer |
| Measuring Current | AC |
| Output Signal | 100mA |
| Sensing Type | Hall Effect |
| Primary Current | 500 AMPERE |
| Supply Voltage | 24 V DC |
| Mounting Type | Panel Mount |
| Brand | LEM |
| Power | 2 A |
| Voltage | 220 V |
| Usage/Application | Industrial |
| Frequncy | 50 Hz |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
The LF 510‑S series transducers are closed‑loop Hall‑effect current sensors that provide galvanically isolated current measurement with excellent accuracy and fast dynamic response. These sensors are designed for panel‑mount installation in industrial power systems and are suitable for a wide range of applications where precise current measurement is necessary.
🔌 Core Technical SpecificationsPrimary Characteristics
Nominal Primary Current (I<sub>PN</sub>): 500 A RMS — continuous rated primary current capacity.
Measuring Range: Approximately ±800 A (DC/AC), allowing measurement of currents beyond the nominal rating.
Output Type: Current output, typically 100 mA nominal for rated primary current.
Technology: Closed‑loop Hall‑effect — provides high accuracy, linearity, and low offset drift over temperature.
Accuracy: Approximately ±0.6 % of nominal current under specified conditions.
Response Time: Fast response (~500 ns typical) for dynamic current measurement.
Electrical Supply & Interface
Supply Voltage: External bipolar DC supply, typically ±14.25 V to ±25.2 V or similar range.
Measured Signal: AC, DC, and pulsed current measurement with current output proportional to primary current.
Operating Temperature Range: Typically –40 °C to +85 °C — suitable for industrial usage.
Mounting: Designed for panel mounting; robust plastic housing with a current aperture for a conductor to pass through.
Aperture: Typical sizes include 30 mm diameter or variations for primary conductor placement.
Galvanic Isolation: Provides reinforced electrical isolation between the primary current path and the secondary measurement circuit, enhancing safety and reducing interference.
Compliance: Often meets major safety and isolation standards (e.g., IEC 61010‑1, UL 508), ensuring industrial safety.
Closed‑Loop Hall‑Effect Design
Reduces offset errors and improves accuracy compared to open‑loop Hall designs.
High immunity to external magnetic disturbances and noise.
Performance
Excellent linearity over wide current ranges.
Low temperature drift across operational range.
Ideal for precision current measurement in:
Variable frequency drives (VFDs) and motor control inverters
Uninterruptible power supplies (UPS) and battery‑powered systems
Power supplies and welders
Renewable energy inverters and chargers
Industrial automation and monitoring equipment
₹ 21000 / Piece Get Latest Price
| Current Range | –1500 A to +1500 A |
| Transducer Type | Pressure Transducer |
| Measuring Current | AC |
| Output Signal | 228mA |
| Sensing Type | Hall Effect |
| Primary Current | 1000 AMPERE |
| Supply Voltage | 15 V DC |
| Mounting Type | Panel Mount |
| Brand | LEM |
| Part Number | LF1005S SP21 |
| Usage/Application | INVERTER |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
₹ 3000 / Piece Get Latest Price
| Current Range | 0-600 A |
| Measuring Current | AC |
| Output Signal | 0-5 V |
| Sensing Type | Hall Effect |
| Primary Current | 300 A |
| Supply Voltage | 15 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 1 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
HTB300-P/SP11 is a Hall-effect current transducer manufactured by LEM.
It is designed for accurate measurement of AC, DC, and pulsed currents.
Provides galvanic isolation between:
Primary circuit (high power)
Secondary circuit (measurement/control electronics)
Part of the HTB series, covering current ranges from 50 A to 400 A.
Uses open-loop Hall Effect technology:
Magnetic field generated by primary current is sensed
Converted into a proportional voltage output
No direct electrical connection between input and output → safe isolation
Nominal current (IPN): 300 A
Measurement range: up to ±600 A
Output signal: Analog voltage (±4 V at nominal current)
High isolation voltage: 2.5 kV
Wide supply voltage: ±12 V to ±15 V
Low power consumption
Fast response time (few microseconds range typical for HTB series)
Compact PCB-mounted design
High immunity to electromagnetic interference
Nominal current (IPN): 300 A
Measuring range (IP): ±600 A
Suitable for:
DC
AC
Pulsed currents
Output voltage (Vout): ±4 V at IPN
Output resistance: ~100 Ω
Supply voltage (Vc): ±12 V to ±15 V
Current consumption: < ±15 mA
Accuracy: ~±1%
Linearity: very good (typical for Hall sensors)
Bandwidth: suitable for dynamic current measurement (DC to tens of kHz range typical)
Response time: ~3 µs (typical for HTB series)
Isolation test voltage: 2.5 kV RMS
Isolation resistance: >500 MΩ @ 500 V DC
Ensures safe operation in high-voltage power circuits
Operating temperature:
Typically −40°C to +80°C
Low temperature drift
Stable performance in industrial environments
Mounting: PCB mounting
Aperture (conductor hole): ~16 mm diameter
Compact size: ~4.3 cm² footprint
Optional busbar connection (depending on variant)
Widely used in power electronics systems such as:
AC variable speed drives / motor drives
UPS systems
Switched Mode Power Supplies (SMPS)
Solar inverters & renewable energy systems
Welding equipment
Battery-powered systems
₹ 20000 / Piece Get Latest Price
| Current Range | 0-2100 AMPERE |
| Output Signal | 200mA |
| Sensing Type | Hall Effect |
| Primary Current | 1000 AMPERE |
| Supply Voltage | 24 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The LF1010‑S/SP16 is part of the LEM LF1010 family of current transducers. It’s a closed‑loop Hall‑effect current sensor that allows accurate measurement of electrical current in power systems while maintaining galvanic isolation between the high‑current primary conductor and the low‑voltage measurement circuitry.
This type of transducer is widely used in power electronics, industrial drives, energy metering, renewable energy systems, and protection circuits.
Nominal Primary Current (I<sub>PN</sub>): 1000 A RMS — continuous rated primary current.
Measuring Range: Up to approximately 2100 A (primary rms) — allowing measurement of currents beyond the nominal rating.
Output Type: Current output, proportional to the measured primary current.
Secondary Nominal Signal: Instantaneous output around 200 mA (rms) for the rated primary current.
Accuracy: ±0.4 % of rated primary current under specified conditions.
Supply Voltage: External bipolar DC, typically ±15 V to ±24 V.
Technology: Closed‑loop compensated — high linearity with minimal drift over temperature.
Primary Signal Types: Suitable for AC, DC, and pulsed currents.
Response Time / Bandwidth: Fast dynamic response and wide bandwidth (typical small‑signal bandwidth around ~200 kHz) to capture transient current changes accurately.
Operating Temperature Range: –40 °C to +85 °C — robust for industrial environments.
Mounting: Designed for panel mounting configuration.
Technology Benefits: Closed‑loop design provides excellent offset and linearity performance over temperature and long‑term use.
Provides galvanic isolation between the primary (high‑current) path and the secondary (measurement) circuit, which enhances safety and protects downstream electronics.
Suitable for systems requiring IEC/EN compliance in industrial power measurement applications.
Ideal for use in:
• High‑power inverters and motor drives
• Renewable energy systems (e.g., solar and wind)
• UPS and power supply systems
• Energy metering and power monitoring
• Overcurrent detection, protection circuits, and diagnostic instrumentation
₹ 20000 / Piece Get Latest Price
| Current Range | 0-2500 AMPERE |
| Output Signal | 0-5 V |
| Sensing Type | Hall Effect |
| Primary Current | 1000 AMPERE |
| Supply Voltage | 15 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 1 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The HAT 1000‑S is an open‑loop Hall‑effect current transducer that converts a large primary current into a proportional analog voltage output, while providing galvanic isolation between the high‑current circuit and the measurement/control electronics. It’s built for industrial environments with rugged performance and stable output.
Operating Principle
Hall Effect Technology (Open‑Loop): Measures the magnetic field around the conductor carrying current using a Hall sensor, then converts it into a proportional electrical signal.
Enables measurement of DC, AC, and pulsed currents without direct electrical connection to the primary circuit.
Galvanic Isolation: Primary (high current) and secondary (output/supply) circuits are electrically isolated, improving safety and noise immunity.
₹ 20000 / Piece Get Latest Price
| Current Range | 0-3000 AMPERE |
| Output Signal | 0-5 V |
| Sensing Type | Hall Effect |
| Primary Current | 1000 AMPERE |
| Supply Voltage | 15 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 1 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The HAX 1000‑S is a compact, open‑loop Hall effect current transducer that measures large currents (up to ~1000 A RMS nominal) and provides an isolated analogue voltage output proportional to the sensed current. It ensures galvanic isolation between the high‑power primary circuit and the low‑power measurement/control electronics, making it suitable for industrial environments.
�� Operating PrincipleHall Effect (Open‑Loop): A Hall sensor detects the magnetic field produced by the primary current flowing through the aperture, converting it into an electrical signal.
Bidirectional Measurement: Capable of measuring both positive and negative currents (AC and DC).
Galvanic Isolation: Electrical isolation between the primary current path and the secondary output/supply circuitry enhances safety and noise immunity.
Analogue Output: Produces a proportional voltage output that can be read by ADCs, controllers, or monitoring systems.
| Parameter | Specification |
|---|---|
| Nominal RMS Current (IPN) | 1000 A |
| Measuring Range | ±3000 A (approx. 3× IPN) |
| Output Signal (Analogue) | ±4 V (instantaneous) |
| Supply Voltage | ±15 V DC bipolar |
| Current Consumption | ~±20 mA |
| Internal Output Resistance | ~100 Ω |
| Recommended Load | >1 kΩ |
| Isolation Resistance | >1000 MΩ @ 500 V DC |
| Bandwidth | DC to ~25 kHz (–3 dB) |
| Response Time | <5 µs (to 90 % of final value) |
Accuracy: ±1 % of nominal current (typically measured at 25 °C, excluding offset)
Linearity: ≤ ±1 % over ±IPN range
Offset Voltage:
Electrical offset: < ±20 mV
Hysteresis offset: < ±30 mV after excursion
Temperature Drift:
Offset drift: < ±1 mV/K
Gain temperature coefficient: < ±0.1 %/K |
Operating Temperature: Typically –25 °C to +85 °C (some specifications extend to –40 °C)
Mounting: Panel mount or chassis installation
Number of Channels: Single channel transducer
Construction: Plastic housing with UL 94‑V0 rated case (galvanically isolated aperture and electronics)
The HAX 1000‑S is ideal for use in industrial and power electronics systems including:
✔ Variable speed drives and servo drives
✔ Switched‑mode power supplies (SMPS)
✔ Uninterruptible power supplies (UPS)
✔ Battery‑powered systems and renewable energy inverters
✔ Welding power supplies and power converters
✔ Motor controllers and current monitoring systems
₹ 20000 / Piece Get Latest Price
| Current Range | 0-5500 AMPERE |
| Output Signal | 0-5 V |
| Sensing Type | Hall Effect |
| Primary Current | 2500 AMPERE |
| Supply Voltage | 15 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 1 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The HAX 2500‑S is a compact open‑loop Hall effect current transducer from LEM’s HAX series that provides an analogue voltage output proportional to the primary current while offering high galvanic isolation between the primary (power) and secondary (measurement) circuits. It’s designed for industrial environments where robust, accurate current sensing of AC, DC, and pulsed currents is required.
Principle of operation: Hall‑effect open‑loop sensor detects magnetic field from current flowing through the aperture and produces an isolated electrical signal.
Isolation: High isolation between primary and secondary circuits improves measurement safety and noise immunity.
Output: Instantaneous analogue output voltage proportional to current.
₹ 20000 / Piece Get Latest Price
| Current Range | 0-4500 AMPERE |
| Output Signal | 0-5 V |
| Sensing Type | Hall Effect |
| Primary Current | 1500 AMPERE |
| Supply Voltage | 15 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 1 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The HAX 1500‑S is a compact Hall‑effect open‑loop current transducer that provides galvanic isolation between a primary current conductor and the measurement electronics. It converts high primary current into a proportional analogue voltage output suitable for control, monitoring, or data‑acquisition systems in industrial power conversion and motor control applications.
Measuring principle: Hall effect with open‑loop architecture.
Primary current type: AC, DC, and pulsed currents.
Isolation: Electrical isolation between primary and secondary circuits.
₹ 20000 / Piece Get Latest Price
| Measuring Current | AC |
The HAX 1000‑S is a compact, open‑loop Hall effect current transducer that measures large currents (up to ~1000 A RMS nominal) and provides an isolated analogue voltage output proportional to the sensed current. It ensures galvanic isolation between the high‑power primary circuit and the low‑power measurement/control electronics, making it suitable for industrial environments.
Operating Principle
Hall Effect (Open‑Loop): A Hall sensor detects the magnetic field produced by the primary current flowing through the aperture, converting it into an electrical signal.
Bidirectional Measurement: Capable of measuring both positive and negative currents (AC and DC).
Galvanic Isolation: Electrical isolation between the primary current path and the secondary output/supply circuitry enhances safety and noise immunity.
Analogue Output: Produces a proportional voltage output that can be read by ADCs, controllers, or monitoring systems.
Amit Sanghvi (Proprietor)
Sanghvi Electronics
Ground Floor, Office No.1, Killedar Mansion, 7/7a, Musa Kiledar Street, K.K. Marg, Byculla, Jacob, Circle, Satrasta
Mumbai - 400011, Maharashtra, India