Providing you the best range of lf1005-s current transducer, lf310-s current transducer and hat500-s current transducer with effective & timely delivery.
₹ 14500 / Piece Get Latest Price
| Current Range | 0-2400 AMPERE |
| Output Signal | 4-20 mA |
| Sensing Type | Hall Effect |
| Primary Current | 1000 AMPERE |
| Supply Voltage | 24 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The LF1005‑S is a high-precision, closed-loop Hall-effect current transducer designed for AC, DC, and pulsed current measurement in industrial and power electronics applications.
Key Features:
Galvanic isolation between primary and secondary circuits for safe monitoring of high currents.
Closed-loop Hall-effect sensing ensures high accuracy, fast response, and excellent linearity.
Suitable for motor drives, power converters, UPS systems, and renewable energy inverters.
| Parameter | Value |
|---|---|
| Sensing Type | Closed-loop Hall-effect |
| Primary Nominal RMS Current (Ipn) | 1000 A |
| Primary Measuring Range | ±2100 A to ±2400 A depending on model (SP16: ±2100 A, SP36: ±2400 A) |
| Turns Ratio (Primary:Secondary) | 1 : 5000 |
| Secondary Nominal Current (Isn) | 200 mA |
| Output Signal Type | Current output proportional to primary current (converted to voltage via burden resistor) |
| Supply Voltage (Vc) | ±15 V … ±24 V DC (±5 %) |
| Linearity Error | < 0.1 % |
| Overall Accuracy @ Ipn, 25 °C | ±0.4 – 0.5 % |
| Response Time (90 %) | < 1 µs |
| Frequency Bandwidth | DC to 150 kHz |
| di/dt Capability | > 50–100 A/µs depending on model |
Operating Temperature: –40 °C to +85 °C
Storage Temperature: –50 °C to +90 °C
Isolation Voltage: Up to 12 kV RMS (primary-secondary) depending on model
Creepage/Clearance: Designed for reinforced insulation and industrial safety standards (IEC 61010‑1 / EN 50178)
Mounting Type: Through-hole / panel mount, primary conductor passes through central aperture.
Housing: Insulated plastic, UL94-V0 rated
Mass: ~500–700 g depending on model
Secondary Connection: Cable or connector (SP16/SP36 differ in connector type)
High linearity and accuracy over wide current ranges
Fast response suitable for dynamic current measurement
Galvanic isolation ensures safe measurement in high-voltage circuits
Can handle rapid current transients (high di/dt)
Works with AC, DC, and pulsed currents
Variable Frequency Drives (VFDs) and servo drives
UPS and battery-based power systems
Power converters, inverters, and welding equipment
Renewable energy systems and traction applications
₹ 20000 / Piece Get Latest Price
| Current Range | 0-500 AMPERE |
| Output Signal | 100mA |
| Sensing Type | Hall Effect |
| Primary Current | 300 A |
| Supply Voltage | 24 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 0.5 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
The LF 310‑S is a current transducer based on closed‑loop Hall‑effect (compensated) technology. It provides galvanically isolated measurement of AC, DC, and pulsed currents. The device is typically panel‑mounted with a through‑hole aperture for the primary conductor and produces a current output proportional to the measured current.
This type of transducer is widely used in industrial control systems, power supplies, motor drives, inverters, UPS units, and energy monitoring equipment.
| Parameter | Value / Description |
|---|---|
| Technology | Closed‑loop Hall‑effect current transducer (compensated) |
| Primary Nominal Current | 300 A RMS |
| Measuring Range | Approximately ±500 A (DC/AC/pulsed) |
| Output | Current output proportional to the primary current, typically ~150 mA at nominal current |
| Accuracy | ±0.2 % of nominal current overall error over operating range |
| Response Time | ~0.5 µs typical reaction (10 % → 90 %) |
| Supply Voltage | External bipolar DC, typically ±11.4 V to ±21 V (varies by connector/version) |
| Operating Temperature | –40 °C to +85 °C |
| Mounting | Panel mount, aperture ~20 mm diameter for primary conductor |
Closed‑Loop Hall‑Effect: Uses an internal magnetic core and Hall sensor with a feedback compensation loop to provide high linearity, low offset drift, and stable measurement across temperature.
Galvanic Isolation: Primary and secondary circuits are electrically isolated, improving safety and protecting measurement electronics from high voltages.
Current Output: The sensor outputs a secondary current proportional to the primary current, suitable for direct interfacing with measurement systems that accept a current input (e.g., mA interface stages).
Accuracy & Linearity:
Tight overall accuracy (~0.2 % of I<sub>PN</sub>) and very low offset drift over temperature provide precise measurements even in demanding environments.
Bandwidth:
Typical frequency response up to ~100 kHz (–3 dB), allowing faithful tracking of fast current changes and high‑frequency components.
Fast Dynamic Response:
Sub‑microsecond reaction time makes the LF 310‑S suitable for PWM‑driven systems and pulsed current applications.
Aperture Size: Approximately 20 mm through‑hole to allow primary conductor/cable insertion.
Panel Mounting: Rugged mechanical design intended for secure panel installation.
Connectors: Versions may use standard connectors (Molex, JST), depending on suffix (e.g., SP10, SP16, SP20).
Industrial Drives & Motor Controllers
Power Supplies & UPS Systems
Renewable Energy Inverters & Solar Power Systems
Battery Management & DC‑DC Converters
Test & Measurement Equipment
Welding Power Sources
₹ 20000 / Piece Get Latest Price
| Current Range | 0-1500 AMPERE |
| Output Signal | 0-5 V |
| Sensing Type | Hall Effect |
| Primary Current | 500 AMPERE |
| Supply Voltage | 15 V DC |
| Mounting Type | Panel Mount |
| Accuracy | 1 % |
| Frequency Range | 50-400 Hz |
| Phase | Single Phase |
Minimum order quantity: 1 Piece
| Parameter | Value / Notes |
|---|---|
| Technology | Open‑loop Hall‑effect current measurement. |
| Primary Nominal Current (I<sub>PN</sub>) | 500 A RMS. |
| Measuring Range (I<sub>P</sub>) | Up to ±1500 A (approx. 3× nominal). |
| Output Signal | Analog voltage output from –4 V to +4 V at rated current. |
| Supply Voltage | Bipolar DC supply, typically ±15 V. |
| Accuracy | Approx. ±1 % of nominal current (excludes offset conditions). |
| Output Type | Analog voltage proportional to measured current (with a defined transfer slope). |
| Response Bandwidth | DC to ~25 kHz (–3 dB typical), suitable for dynamic current sensing. |
| Mounting Style | Panel mount with through‑hole for the primary conductor. |
Open‑loop Hall effect:
A magnetic Hall sensor detects the magnetic field created by current through the primary conductor.
The sensor produces a proportional voltage output without a closed compensation loop (simpler and lower cost than closed‑loop designs).
Galvanic isolation separates the high‑power current path from the measurement side to protect downstream elec
Operating Temperature: −40 °C to +105 °C allowing use in demanding industrial environments.
Isolation & Insulation: High insulation resistance (>1000 MΩ at 500 V DC) improves safety against high‑voltage stress.
Housing: Insulating plastic case recognized per UL 94‑V0, ensuring flame retardance.
Standards Compliance: Designed to meet industrial safety standards such as EN 50178 and UL 508 (depending on region/version).
DC and AC motor drives
Switched‑mode power supplies (SMPS)
Uninterruptible Power Supplies (UPS)
Battery‑powered systems and chargers
Industrial automation current monitoring
Welding power supplies
Variable‑frequency inverters and power converters